Manufacturer Reverse Osmosis Commercial 800g RO membrane

Request a Quote

Products Details

All we do is usually connected with our tenet " Client very first, Belief first, devoting about the food stuff packaging and environmental security for Manufacturer Reverse Osmosis Commercial 800g RO membrane, We focus on for making great high quality products to offer services for our consumers to establish long-term win-win romance. All we do is usually connected with our tenet " Client very first, Belief first, devoting about the food stuff packaging and environmental security for 800g RO Membrane, Adhering to the management tenet of "Managing Sincerely, Winning by Quality", we try our best to provide excellent products and service to our clients. We look forward to making progress together with domestic and international clients. RO Membrane Price HIDTM Commercial RO Membrane ranks the best brands in China among the RO membrane industry. It has won the trust of numerous clients for feeding the Much better high-quality, Low RO Membrane Price over 11 years. Each membrane is made of HID developed & pre-examined sheet and goes through stringent making processes as well as in-house quality inspection & testing before delivery. HID Membrane has been certified by SGS & China Jiangsu Sanitation Bureau wrt drinking water membrane elements. Model No. Min. Salt Rejection (%) Stabilized Salt Rejection(%) Permeate Flow Rate(gpd) TestTemp. Test Pressure Test Water TDS TFC-3012-200 95 97 200 25℃ 65psi 500ppm TFC-3012-300 95 97 300 25℃ 65psi 500ppm TFC-3012-400 95 97 400 25℃ 80psi 500ppm TFC-3013-400 95 97 400 25℃ 100psi 500ppm TFC-3012-500 94 96 500 25℃ 100psi 500ppm TFC-3213-600 94 96 600 25℃ 100psi 500ppm TFC-3213-800 94 96 800 25℃ 100psi 500ppm 1. Permeate flow rate and salt rejection is based on testing conditions: 25℃, PH 7.5, 20% recovery. 2. Stabilized salt rejection is generally achieved within 24-48 hours of continuous use, depending upon feedwater characteristics and operating conditions. Model No. Maximum  Operating Temperature Maximum  Operating  Pressure Feed Water PH Range,  continuous operation Maximum Feed Water Turbidity Maximum  Feed Water SDI Chlorine  Tolerance TFC-3012-200 45℃ 200psi 4-11 1NTU 5 <0.1ppm TFC-3012-300 45℃ 200psi 4-11 1NTU 5 <0.1ppm TFC-3012-400 45℃ 200psi 4-11 1NTU 5 <0.1ppm TFC-3013-400 45℃ 200psi 4-11 1NTU 5 <0.1ppm TFC-3012-500 45℃ 200psi 4-11 1NTU 5 <0.1ppm TFC-3213-600 45℃ 200psi 4-11 1NTU 5 <0.1ppm TFC-3213-800 45℃ 200psi 4-11 1NTU 5 <0.1ppm

contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

return